FAC-T
CE :: The CE-identification is performed by the manufacturer. The manufacturer, at the manufacturers own responsibility, hereby confirms conformity with the respective EC or EU directives. Conformity in accordance with the Low-voltage Directive and the EMV Directive (interference immunity, emitted interference) is the precondition for the CE-identification for our products.
ENEC :: The ENEC-Symbol is the European safety symbol for luminaires. The test regulations are determined by the European standard 60 598. The ENEC-Symbol is issued in combination with the identification number of a European test center (VDE = 10) This documents that the luminaires have been built and tested in "conformity with the standards" as per the Low-voltage Directive 73/23 EEC.
VDE :: Reiss standard luminaires are VDE-approved. They have the VDE-approval and are continuously tested in strictly stipulated quality controls. These controls are supervised by the VDE.
F :: All luminaires meet the F-conditions. In the event of faulty luminaire the fastening surfaces will not be hotter than 180°C. They may be mounted on inflammable building materials as described in DIN 4102 ignition point of at least 200°C (e.g. wood). Observe the installation instructions in order to avoid incorrect installation.
IP 65 :: dust-tight (no ingression of dust) and protected from jet water (from all directions).
IP 67 :: dust-tight (no ingression of dust) and protected from immersion (with details about pressure and time).

Advice

By clicking on the item numbers listed in the below mentioned tables, you will get a photometric data sheet in PDF format for the respective luminaire type.

T26 (T8) VVG induktiv / low loss ballast
TypAbdeckungAbmessungen*Gewicht
TypeDiffuserDimensions*Weight
PMLBHDKg
clear
FAC-T 1/36W32 161 72012831111056602,4
FAC-T 1/58W32 161 72115831111059003,2
FAC-T 2/36W32 161 72212831681096603,7
FAC-T 2/58W32 161 72315831681099005,1
* mm
T26 (T8) EVG / electronic ballast
TypAbdeckungAbmessungen*Gewicht
TypeDiffuserDimensions*Weight
PMLBHDKg
clear
FAC-T 1/36W42 179 63612831111056602,1
FAC-T 1/58W42 179 63715831111059002,5
FAC-T 2/36W42 179 64812831681096602,9
FAC-T 2/58W42 179 64915831681099003,4
* mm
T16 (T5) EVG / electronic ballast
TypAbdeckungAbmessungen*Gewicht
TypeDiffuserDimensions*Weight
PMLBHDKg
clear
FAC-T 1/28W42 179 63412831111056602,1
FAC-T 1/54W42 179 63512831111056602,1
FAC-T 1/35W70 425 76315831111059002,5
FAC-T 1/49W42 178 99215831111059002,5
FAC-T 1/80W42 179 46715831111059002,5
FAC-T 2/28W42 179 64112831681096602,9
FAC-T 2/54W70 425 76412831681096602,9
FAC-T 2/35W70 425 76515831681099003,4
FAC-T 2/49W42 178 99315831681099003,4
* mm